FPGT Loader has the following new features:
*.gpt project files of version 1.0.2.0 could not be opened. This has been fixed.
For GT7xx panels that do not support the firmware upload, the firmware is pre-installed in the FPGT Loader application folder C:\Program Files (x86)\Panasonic-ID SUNX Control\FPGT Loader 2\Firmware
or C:\Program Files (x86)\Panasonic Industry Control\FPGT Loader 2\Firmware
. Other firmware files from the GTWIN_V3 application folder or from the Panasonic-Website can be added to this folder.
The following firmware is pre-installed:
GT703, GT704: from V1.400 to V1.470
GT707: from V1.400 to V1.660
To prevent unwanted overwriting of GT panel password settings, the password settings of the project and the GT panel are checked before download. If there are differences, the user will be asked how to proceed.
Project upload failed for GT7xx panels with the following firmware versions:
GT703, GT704: V1.460, V1.470
GT707: V1.650, V1.660
The file open dialog did not show the PLC files (*.plc). This has been fixed.
Fixed crash that may occur when opening GT panel project files (*.gpt) from FPGT Loader 2.2.0.0 or older with version 2.3.0.0.
Suppressed warning that appears in version 2.3.0.0 when the project files (*.plc, *.gpt) have older version numbers.
New features
Support of the GT7xx series panels like GT703, GT704, GT707, GT710
Implemented a new warning that appears when the project files (*.plc, *.gpt) have different version numbers.
Increased the version number of GT panel project files (*.gpt). Therefore, a warning appears when existing GT panels project files are opened.
New features
For PLCs: Variable WR area sizes in PLC types such as FP-XH and FP0H that use the new system register Size of the internal flag area (1) are supported.
For GT panels: A new checkbox prevents unintended downloading of operation security settings to a GT panel
Updated features
FP_Connect Version 2.2.1.0 will be used
Bug fix to upload more than 32000 steps, e.g. for FP-SIGMA 40K. The communication settings are retained when the communication settings dialog is closed and opened again.
Updated features
FP_Connect Version 2.2.0.0 will be used
Passwords are now supported for all PLC types, including FP7, FP-X, FP-XH, and FP0H.
The password is contained in the upload and download data. If the password in the project is different from the password in the target device, the new password is set in the target device after download. If the project has no password protection, the password in the target device is removed.
Upload and download is supported for all PLC types, including FP-XH Ethernet types.
New features
FP_Connect Version 2.1.0.0 will be used
Added new PLC type series FP0H including the option to read/write flash data
Bug fix
Font file could not be transferred into the GT panel.
Bug fix
Project could not be transferred into a GT panel if the GT panel was connected via FPWebServer, Web Expansion and USB cable.
Updated feature
FP_Connect Version 2.0.6.1 will be used
The option “Do not overwrite hold-type registers” is set as default setting
Updated feature
FP_Connect Version 2.0.5.0 will be used
For FP7 the option “Do not overwrite hold-type registers” is supported
Updated feature
FP_Connect Version 2.0.4.0 will be used
The generated project files *.plc cannot be opened from older versions anymore
New feature
Supports FP7 with the following restrictions:
Program code and PLC data will be up- and downloaded
Passwords are not supported
The option “Do not overwrite hold-type registers” is not supported
Bug fix
Fixed crash that may occur during download of data into GT panel.
Solved PLC download error
Added GT03-E panel
Solved PLC download error
Added GT03-E panel
New feature
Windows 8 64-bit compatible FP0R USB driver
Windows 7/8 64-bit compatible GT USB driver
New feature
Added GT32-E panel
Bug fix
User interface is now correct
Bug fix
Solved a bug in Download *.fp file which prevented the download if the PLC was upload-protected. Only FP0R PLCs were affected.
Bug fix
Solved a bug that prevents the download of program and system registers when the PLC upload protection is activated
Bug fix
Solved PLC login error
New feature
Download of *.fp files (FPWIN GR) to the PLC
Reading the RTC (real-time clock) from the PLC
Setting the RTC in the PLC
Displaying the communication parameters in the status bar
Bug fix
User interface is now correct
New feature
Added user interface in Spanish
Online help for all languages added
Updated feature
Changing the language now works if the user has administrative rights.
New feature
Added GT02 panel
Added WR register