Import of GR/GR7 addresses and constants:
Import of REAL addresses as RDT100
Import of LREAL addresses as LRDT100
Import of DOUBLE addresses as DDT100
Only for FP7: Import of UINT addresses as UDT100 and import of UDINT addresses as UDDT100
Direct import of constants with index modifiers
Direct import of integer devices and K and H constants, especially for REAL arguments
16-bit integer device, e.g. %DT100 is converted to §DT100
32-bit integer device, e.g. #DT100 is converted to §DDT100
FPWIN GR/FPWIN GR7 program:
Conversion result in Control FPWIN Pro7:
FPWIN GR/FPWIN GR7 program:
Conversion result in Control FPWIN Pro7:
In FPWIN GR/FPWIN GR7, subroutines with multiple entrances and only one exit (RET) can be programmed for the FP2/FP2SH/FP10SH.
When, for example, Call 11 is executed, the program parts (1) to (4) are executed. When CALL 13 is executed, the program parts (3) and (4) are executed.
Control FPWIN Pro7 converts each program part of a subroutine entry into an Control FPWIN Pro7 subroutine as follows:
The FPWIN GR/FPWIN GR7 instruction Call 11 is converted into 4 boxes: GR_Subroutine11 to GR_Subroutine14 in ascending order, each of which calls its corresponding program part (1) to (4).
Call 13 is converted into 2 boxes: GR_Subroutine13 and GR_Subroutine14, each of which calls its corresponding program part (3) and (4).