Option |
Setting |
---|---|
Initialization of variables after download in PROG mode
|
Choose a desired option. |
Maximum number of program steps for periodic interrupt |
The number of steps depends on the size of the periodic interrupt. An error message is output if the size of the periodic interrupt does not fit. If you enter an invalid number, the valid range of entries is displayed in a message box. When you have changed the value, you have to re-compile the project and execute Download program code and PLC configuration to PLC. |
Default string length (characters) |
Enter the number of characters you want the default string length to be (max. 255 characters). |
Indexed function block instances |
Using this option you can specify how the compiler generates program codes for function blocks that you, the user, created yourself. This option is only available for some controllers. |
Path\file name to store compile/check messages |
Here you enter the name and path of a file (e.g. C:\directory\name.txt) where all messages are stored which are displayed in the dialog box Compile/check pane. Each time Compile incrementally... is executed, the content of this file is automatically overwritten. or / |
Stop check at number of errors Stop check at number of warnings |
Enter the number of errors/warnings after which you want the compile process to stop. |
To activate the standard settings for your compiler, select Default.