I/O map

Description for FP2/FP2SH
  1. Double-click PLC in the navigator.
  2. Open I/O map from navigator
  3. Double-click I/O map
  4. Set total number of slots in Number of slots

    Vacant slots are grayed and marked with 3 asterisks (***).

  5. Select desired slot
  6. Define
  7. Select desired unit type
  8. OK
  9. Repeat for all other units
  10. Select OK in the Master I/O map configuration dialog

    You can save the I/O configuration with the project, compile it and transfer it into the PLC or, if you are in online mode, transfer the I/O configuration directly into the PLC with Online > Download program code and PLC configuration to PLC .

    The following abbreviations are used for I/O configurations:

    Abbreviation

    Description

    16X

    Reserves 16 digital inputs

    32X

    Reserves 32 digital inputs

    64X

    Reserves 64 digital inputs

    128X

    Reserves 128 digital inputs

    16Y

    Reserves 16 digital outputs

    32Y

    Reserves 32 digital outputs

    64Y

    Reserves 64 digital outputs

    128Y

    Reserves 128 digital outputs

    0E

    Terminal not used, no digital points reserved

    16E

    Terminal not used, but 16 digital points reserved

    32E

    Terminal not used, but 32 digital points reserved

    64E

    Terminal not used, but 64 digital points reserved

    128E

    Terminal not used, but 128 digital points reserved

    16SX

    Reserves 16 digital inputs for an intelligent unit

    32SX

    Reserves 32 digital inputs for an intelligent unit

    64SX

    Reserves 64 digital inputs for an intelligent unit

    128SX

    Reserves 128 digital inputs for an intelligent unit

    16SY

    Reserves 16 digital outputs for an intelligent unit

    32SY

    Reserves 32 digital outputs for an intelligent unit

    64SY

    Reserves 64 digital outputs for an intelligent unit

    128SY

    Reserves 128 digital outputs for an intelligent unit

    0SE

    Terminal unused, no digital points reserved for an intelligent unit

    16SE

    Terminal unused, but 16 digital points reserved for an intelligent unit

    32SE

    Terminal unused, but 32 digital points reserved for an intelligent unit

    64SE

    Terminal unused, but 64 digital points reserved for an intelligent unit

    128SE

    Terminal unused, but 128 digital points reserved for an intelligent unit

Modified on: 2019-12-10Feedback on this pagePanasonic hotline