F180_DUT

This DUT can be used with the following instruction(s): F180_SCR_DUT

Elements of the DUT (identifiers):

ScreenControl(WORD)
  • High byte
    1.  (1) Undefined (Specify 0)
      NOTE

      When a value with a decimal point is to be displayed in the Signed Dec 5 digits mode, the value(s) before the decimal point should be displayed.

    2.  (2) Upper setting
    3.  (3) Lower setting

      0: not displayed, 1: displayed

  • Low byte

    0: not displayed, 1: displayed

UpperDisplayControl(WORD)
  • High byte (Display control: upper section)

    1.  (1) Digit display
    2.  (2) Color

      00: Undefined (displayed in green when defined)

      01: Green

      10: Red

      11: Orange

    3.  (3) Zero suppression

      0: Available

      1: Not available (all digits displayed)

  • Low byte (Display control: lower section)

    1.  (1) Upper display mode

      000: Signed Dec 5 digits

      001: Hex 4 digits or BCD 4 digits

      010: Bit

      011: ASCII code of five characters

      100: 7-segment Data

      101: Undefined

      110: Undefined

      111: Undefined

      101 and later: Undefined.

      Error occurs when undefined data is specified

    2.  (2) Decimal point display
LowerDisplayControl(WORD)

Same setting as UpperDisplayControl

Modified on: 2020-10-01Feedback on this pagePanasonic hotline