The PLC keeps the values of hold-type memory areas without battery. The address range of hold-type memory areas is dependent on the PLC type.
PLC |
Memory area |
Hold-type memory area (without battery) |
|
---|---|---|---|
Start address |
Last address |
||
FP0R C10/14/16 |
Data registers DT |
DT12000 |
DT12312 |
Internal flag words WR |
WR248 |
WR255 |
|
Timer/counter elapsed value area EV |
EV1008 |
EV1023 |
|
FP0R C32/T32 |
Data registers DT |
DT32450 |
DT32762 |
Internal flag words WR |
WR248 |
WR255 |
|
Timer/counter elapsed value area EV |
EV1008 |
EV1023 |
|
FP0H C32 (24k) |
Data registers DT |
DT65218 |
DT65530 |
Internal flag words WR |
WR248 |
WR255 |
|
Timer/counter elapsed value area EV |
EV1008 |
EV1023 |
|
FP0H C32 (32k) |
Data registers DT |
DT32450 |
DT32760 |
Internal flag words WR |
WR504 |
WR511 |
|
Timer/counter elapsed value area EV |
EV1008 |
EV1023 |
|
FP0H C32E (24k) |
Data registers DT |
DT65218 |
DT65530 |
Internal flag words WR |
WR504 |
WR511 |
|
Timer/counter elapsed value area EV |
EV1008 |
EV1023 |
|
FP0H C32E (32k) |
Data registers DT |
DT32450 |
DT32762 |
Internal flag words WR |
WR504 |
WR511 |
|
Timer/counter elapsed value area EV |
EV1008 |
EV1023 |
|
FP0H C32E (40k) |
Data registers DT |
DT24258 |
DT24570 |
Internal flag words WR |
WR504 |
WR511 |
|
Timer/counter elapsed value area EV |
EV1008 |
EV1023 |
|
FP0H C32E (60k) |
Data registers DT |
DT11970 |
DT12282 |
Internal flag words WR |
WR504 |
WR511 |
|
Timer/counter elapsed value area EV |
EV1008 |
EV1023 |
|
FP7 CPS21 (32k/64k) |
Internal flag words WR |
WR0 |
All |
Data registers DT |
DT0 |
DT131071 |
|
FP7 CPS31/41 (depending on the memory settings) |
Data registers DT |
DT0 |
max. DT262143 |
FP-XH C14 |
Data registers DT |
DT11970 |
DT12282 |
Internal flag words |
WR504 |
WR511 |
|
Timer/counter elapsed value area |
EV1008 |
EV1023 |
|
FP-XH C30/40/60 (12k) |
Data registers DT |
DT65218 |
DT65530 |
Internal flag words WR |
WR504 |
WR511 |
|
Timer/counter elapsed value area EV |
EV1008 |
EV1023 |
|
FP-XH C30/40/60 (32k) |
Data registers DT |
DT32450 |
DT32762 |
Internal flag words WR |
WR504 |
WR511 |
|
Timer/counter elapsed value area EV |
EV1008 |
EV1023 |
|
FP-XH C30/40/60 (40k) |
Data registers DT |
DT11970 |
DT12282 |
Internal flag words WR |
WR504 |
WR511 |
|
Timer/counter elapsed value area EV |
EV1008 |
EV1023 |
|
FP0/FP-e |
Data registers DT |
DT1652 |
DT1657 |
Internal flag words WR |
WR61 |
WR62 |
|
Timer/counter elapsed value area EV |
EV140 |
EV143 |
|
FP0 C10/14/16 |
Data registers DT |
DT1652 |
DT1657 |
Internal flag words WR |
WR61 |
WR62 |
|
Timer/counter elapsed value area EV |
EV140 |
EV143 |
|
FP0 C32 |
Data registers DT |
DT6112 |
DT6141 |
Internal flag words WR |
WR55 |
WR62 |
|
Timer/counter elapsed value area EV |
EV128 |
EV143 |
|
FPS 12k |
Data registers DT |
DT32710 |
DT32762 |
Internal flag words WR |
WR90 |
WR97 |
|
Timer/counter elapsed value area EV |
EV1008 |
EV1023 |
|
FPS 32k (Ver.3.x) |
Data registers DT |
DT32710 |
DT32762 |
Internal flag words WR |
WR248 |
WR255 |
|
Timer/counter elapsed value area EV |
EV1008 |
EV1023 |
|
FP-X C14 |
Data registers DT |
DT12230 |
DT12280 |
Internal flag words WR |
WR248 |
WR255 |
|
Timer/counter elapsed value area EV |
EV1008 |
EV1023 |
|
FP-X C30/C60 |
Data registers DT |
DT32710 |
DT32760 |
Internal flag words WR |
WR248 |
WR255 |
|
Timer/counter elapsed value area EV |
EV1008 |
EV1023 |
FP0H, FP-XH, FP-X, FPS (compact PLCs with an optional battery):
If you mount a battery, the whole data memory (adjustable) can be used as a hold-type memory.
If you do not mount a battery, the data memory area specified in the columns under "Hold-type memory area (without battery)" in the table above can be used as a hold-type memory.
Without battery, the whole data memory has a limited holding power, which lasts for about 60 seconds (valid for an FP0H PLC). After this time, all memory areas apart from the standard hold-type memory are initialized to value 0.
FP0 T32CP and FP0R T32CP:
A maintenance-free, built-in supercap accumulator is used to hold the whole data memory (adjustable).
The backup time ranges from 14 to 50 days and depends on the ambient temperature.
The typical service life of the accumulator is up to 10 years at an ambient temperature of 25°C.
When the accumulator is empty, the PLC initializes the memory to value 0.
The data memory area specified in the columns under "Hold-type memory area (without battery)" in the table above can be used as a hold-type memory even if the accumulator is empty.
Detailed information: For PDF files, please refer to Panasonic Download Center
FP0R F32CP: Data registers of 32765 words can be written to the built-in F-ROM, which serves as a hold-type memory area.
FP7:
If you do not mount a battery, the data memory area specified in the columns under "Hold-type memory area (without battery)" in the table above can be used as a hold-type memory.
Project data (program and PLC configuration) and operation memory (except for clock/calendar data) are automatically backed up by the built-in non-volatile memory (Flash-ROM).
The clock/calendar function keeps working for about one week thanks to the built-in capacitor even if no battery is used. In order to charge the built-in capacitor, supply power to the CPU unit for at least 30 minutes.