FP_SYSTEM_MONITOR_VERIFY_ERROR_DUT

This DUT can be used with the following instruction(s): FP_SYSTEM_MONITOR_READ

Elements of the DUT (identifiers):

wVerifyErrorSlot_1_16 (WORD)

Verify error slot 1–16

Bit 0 = Slot 1, Bit 15 = Slot 16

wVerifyErrorSlot_17_32 (WORD)

Verify error slot 17–32

Bit 0 = Slot 17, Bit 15 = Slot 32

wVerifyErrorSlot_33_48 (WORD)

Verify error slot 33–48

Bit 0 = Slot 33, Bit 15 = Slot 48

wVerifyErrorSlot_49_64 (WORD)

Verify error slot 49–64

Bit 0 = Slot 49, Bit 15 = Slot 64

wVerifyErrorFirstTime_YYMM (WORD)

First occurrence of verify error in BCD time in BCD format Year, Month

wVerifyErrorFirstTime_DDHH (WORD)

First occurrence of verify error in BCD time in BCD format Day, Hour

wVerifyErrorFirstTime_MMSS (WORD)

First occurrence of verify error in BCD time in BCD format Minute, Second

wVerifyMethod (WORD)

Modified on: 2019-12-10Feedback on this pagePanasonic hotline