Monitoring the register

Monitor > Special flags and registers > Data recording
sys_iSampleTraceInterval Sampling interval 0 to 3000 x 10 ms
sys_bIsSamplingTraceIntervalTriggered Start of sampling per cycle flag = 0 (FALSE) per time interval = 1 (TRUE)
sys_bIsSamplingTraceStopTriggerActive Sampling trigger flag = 1 (TRUE), if trigger has been defined
sys_bIsSamplingTraceDone End of sampling = 1 (TRUE)
sys_bIsSamplingTraceActive Sampling ON flag = 1 (TRUE), if sampling procedure is active (record values)
NOTE

The sampling trace flags (R902C–R902F) are set to FALSE (see status of sampling trace with Monitor > Special flags and registers > Data recording):

  • sys_bIsSamplingTraceIntervalTriggered

  • sys_bIsSamplingTraceDone

  • sys_bIsSamplingTraceStopTriggerActive

  • sys_bIsSamplingTraceActive

Modified on: 2019-12-10Feedback on this pagePanasonic hotline