HscControl_ElapsedValueContinue

Continues counting after reset

This instruction resumes counting on the channel specified by iChannel after a reset of the elapsed value using HscControl_ElapsedValueReset. Bit 0 of the Writing the high-speed counter control code is set to FALSE.

Parameters

Input

iChannel (INT)

High-speed counter channel:

FPS: 0, 2

FP-X R: 0, 1

FP-X 16K C14T: 0, 1, 2

FP-X 32K C30T, C60T: 0, 1, 2, 3

FP0R: 0, 1, 2, 3

FP0: 0, 1

FP-e: 0, 1

Example

POU header

All input and output variables used for programming this function have been declared in the POU header. The same POU header is used for all programming languages.

	VAR
		bElapsedValueContinue: BOOL:=FALSE;
		iChannel: INT:=0;
END_VAR

POU body

When the variable bElapsedValueContinue is set to TRUE, counting resumes on the channel specified by iChannel.

LD body

BODY
    WORKSPACE
        NETWORK_LIST_TYPE := NWTYPELD ;
        ACTIVE_NETWORK := 0 ;
    END_WORKSPACE
    NET_WORK
        NETWORK_TYPE := NWTYPELD ;
        NETWORK_LABEL :=  ;
        NETWORK_TITLE :=  ;
        NETWORK_HEIGHT := 5 ;
        NETWORK_BODY
B(B_F,HscControl_ElapsedValueContinue!,,12,0,28,4,,?DEN?DiChannel?AENO);
B(B_VARIN,,iChannel,10,2,12,4,);
B(B_CONTACT,,bElapsedValueContinue,5,1,7,3,);
L(1,2,5,2);
L(7,2,12,2);
L(1,0,1,5);
        END_NETWORK_BODY
    END_NET_WORK
    NET_WORK
        NETWORK_TYPE := NWTYPELD ;
        NETWORK_LABEL :=  ;
        NETWORK_TITLE :=  ;
        NETWORK_HEIGHT := 5 ;
        NETWORK_BODY
L(1,0,1,5);
        END_NETWORK_BODY
    END_NET_WORK
END_BODY

ST body

if (bElapsedValueContinue) then
    HscControl_ElapsedValueContinue(iChannel := iChannel);
end_if;