PulseInfo_ReadAccelerationForbiddenAreaStartingPosition

Read acceleration forbidden area starting position

This instruction reads the starting position of an acceleration forbidden area. If the elapsed value crosses over this position when the speed is being changed, acceleration cannot be continued any more.

Parameters

Input

iChannel (INT)

Pulse output channel:

FPS: 0, 2

FP-X/XH R: 0, 1

FP-X/XH 16K C14T: 0, 1, 2

FP-X/XH 32K C30T: 0, 1, 2, 3

FP-X/XH 32K C60T: 0, 1, 2, 3, 4, 5

FP0R: 0, 1, 2, 3

FP0: 0, 1

FP-e: 0, 1

Output

VAR_OUT (DINT)

Result stores the start position of the acceleration forbidden area

Example

POU header

All input and output variables used for programming this function have been declared in the POU header. The same POU header is used for all programming languages.

	VAR
		iChannel: INT:=0;
		diForbiddenAreaStartingPosition: DINT:=0;
END_VAR

LD body

BODY
    WORKSPACE
        NETWORK_LIST_TYPE := NWTYPELD ;
        ACTIVE_NETWORK := 0 ;
    END_WORKSPACE
    NET_WORK
        NETWORK_TYPE := NWTYPELD ;
        NETWORK_LABEL :=  ;
        NETWORK_TITLE :=  ;
        NETWORK_HEIGHT := 5 ;
        NETWORK_BODY
B(B_F,PulseInfo_ReadAccelerationForbiddenAreaStartingPosition!,,7,1,32,4,,?DiChannel?C);
B(B_VARIN,,iChannel,5,2,7,4,);
B(B_VAROUT,,diForbiddenAreaStartingPosition,32,2,34,4,);
L(1,0,1,5);
        END_NETWORK_BODY
    END_NET_WORK
    NET_WORK
        NETWORK_TYPE := NWTYPELD ;
        NETWORK_LABEL :=  ;
        NETWORK_TITLE :=  ;
        NETWORK_HEIGHT := 5 ;
        NETWORK_BODY
L(1,0,1,5);
        END_NETWORK_BODY
    END_NET_WORK
    NET_WORK
        NETWORK_TYPE := NWTYPELD ;
        NETWORK_LABEL :=  ;
        NETWORK_TITLE :=  ;
        NETWORK_HEIGHT := 5 ;
        NETWORK_BODY
L(1,0,1,5);
        END_NETWORK_BODY
    END_NET_WORK
END_BODY

ST body

diForbiddenAreaStartingPosition := PulseInfo_ReadAccelerationForbiddenAreaStartingPosition(iChannel := iChannel);

Modified on: 2019-01-25Feedback on this pagePanasonic hotline