Get MEWNET-W network status information
This instruction gets the MEWNET-W network status information about the MEWNET-W unit in the slot number specified by s_Slot.
Input
Slot number of expansion unit
Output
Stores the network status information in the FP_MEWNET_W_NETWORK_STATUS_DUT.
All input and output variables used for programming this function have been declared in the POU header.The same POU header is used for all programming languages.
VAR
bEnable: BOOL:=FALSE;
iSlot: INT:=0;
dutMewnetWNetworkStatus: FP_MEWNET_W_NETWORK_STATUS_DUT;
END_VAR
When the variable bEnable is set to TRUE, the function is executed.
BODY
WORKSPACE
NETWORK_LIST_TYPE := NWTYPELD ;
END_WORKSPACE
NET_WORK
NETWORK_TYPE := NWTYPELD ;
NETWORK_LABEL := ;
NETWORK_TITLE := ;
NETWORK_HEIGHT := 4 ;
NETWORK_BODY
B(B_CONTACT,,bEnable,4,1,6,3,);
B(B_F,FP_MEWNET_W_GET_NETWORK_STATUS!,,15,0,34,4,,?DEN?Ds_Slot?AENO?Cd_dutMewnetWNetworkStatus);
B(B_VARIN,,iSlot,13,2,15,4,);
B(B_VAROUT,,dutMewnetWNetworkStatus,34,2,36,4,);
L(1,0,1,4);
L(1,2,4,2);
L(6,2,15,2);
END_NETWORK_BODY
END_NET_WORK
END_BODY
If (bEnable) Then
FP_MEWNET_W_GET_NETWORK_STATUS(s_Slot := iSlot,
d_dutMewnetWNetworkStatus => dutMewnetWNetworkStatus);
End_if;