Checks if high-speed counter channel is enabled
This instruction returns TRUE if the high-speed counter channel specified by iChannel has been enabled in the system registers and is supported by the selected PLC type.
Input
High-speed counter channel:
FPS: 0, 2
FP-X R: 0, 1
FP-X 16K C14T: 0, 1, 2
FP-X 32K C30T, C60T: 0, 1, 2, 3
FP0R: 0, 1, 2, 3
FP0: 0, 1
FP-e: 0, 1
Output
TRUE if the channel specified by iChannel is enabled
All input and output variables used for programming this function have been declared in the POU header. The same POU header is used for all programming languages.