Starts position control
This instruction sets and resets bit 6 of the pulse output control code to start position control on the channel specified by iChannel. The position control trigger is used with the JOG operation instructions PulseOutput_Jog_Positioning0_FB and PulseOutput_Jog_Positioning1_FB.
Input
Pulse output channel:
FPS: 0, 2
FP-X/XH R: 0, 1
FP-X/XH 16K C14T: 0, 1, 2
FP-X/XH 32K C30T: 0, 1, 2, 3
FP-X/XH 32K C60T: 0, 1, 2, 3, 4, 5
FP0R: 0, 1, 2, 3
FP0: 0, 1
FP-e: 0, 1
All input and output variables used for programming this function have been declared in the POU header. The same POU header is used for all programming languages.
VAR
bJogPositionControl: BOOL:=FALSE;
iChannel: INT:=0;
END_VAR
BODY
WORKSPACE
NETWORK_LIST_TYPE := NWTYPELD ;
ACTIVE_NETWORK := 0 ;
END_WORKSPACE
NET_WORK
NETWORK_TYPE := NWTYPELD ;
NETWORK_LABEL := ;
NETWORK_TITLE := ;
NETWORK_HEIGHT := 5 ;
NETWORK_BODY
B(B_F,PulseControl_JogPositionControl!,,11,0,26,4,,?DEN?DiChannel?AENO);
B(B_VARIN,,iChannel,9,2,11,4,);
B(B_CONTACT,,bJogPositionControl,6,1,8,3,);
L(1,0,1,5);
L(1,2,6,2);
L(8,2,11,2);
END_NETWORK_BODY
END_NET_WORK
NET_WORK
NETWORK_TYPE := NWTYPELD ;
NETWORK_LABEL := ;
NETWORK_TITLE := ;
NETWORK_HEIGHT := 5 ;
NETWORK_BODY
L(1,0,1,5);
END_NETWORK_BODY
END_NET_WORK
NET_WORK
NETWORK_TYPE := NWTYPELD ;
NETWORK_LABEL := ;
NETWORK_TITLE := ;
NETWORK_HEIGHT := 5 ;
NETWORK_BODY
L(1,0,1,5);
END_NETWORK_BODY
END_NET_WORK
END_BODY
if (bJogPositionControl) then
PulseControl_JogPositionControl(iChannel := iChannel);
end_if;